现浇楼板对框架结构柱梁强度比的影响研究 马千里,叶列平,陆新征,马玉虎 (清华大学土木工程系,北京,100084) 汶川地震建筑震害分析与重建研讨会论文集, 2008.6, 北京 摘 要:“强柱弱梁”屈服机制是框架结构的抗震设计原则,但由于现浇楼板等因素的影响,实际框架结构并不能实现梁铰屈服机制。本文总结了大量研究者的试验和分析结果,并通过算例证明楼板对框架梁的负弯矩承载力有较大提高,因此建议将框架梁等效为T形或者G型梁进行设计计算,在此基础上按规范要求考虑柱端弯矩放大系数;或将楼板钢筋考虑为超配钢筋,进一步提高柱端弯矩放大系数,使实际结构真正实现“强柱弱梁”的屈服机制。 关键词:框架结构,强柱弱梁,柱梁强度比,楼板,有效翼缘宽度 |
|
参考文献 [1] GB50011-2001, 建筑结构抗震设计规范条文说明[S]. 中国建筑工业出版社, 北京, 2002. [2] GB50011-2001, 建筑结构抗震设计规范[S]. 中国建筑工业出版社, 北京, 2002. [3] 蒋永生, 陈忠范, 周绪平, 鲁宗悫. 整浇梁板的框架节点抗震研究[J]. 建筑结构学报, 1994, 12(3): 11~16. [4] 叶列平, 陆新征, 马千里等. 混凝土结构抗震非线性分析模型、方法及算例[J]. 工程力学, 2006, 23(sup.2): 131-140. [5] 唐九如. 钢筋混凝土框架节点抗震[M]. 东南大学出版社, 南京, 1989. [7] Leon R.T. The Effect of Floor Member Size on the Behavior of Reinforced Concrete Beam-Column Joints[J]. Proceedings of 8th World Conference on Earthquake Engineering, San Francisco, Calif., July, 1984: 445~452. [8] Leon R.T. and Jirsa J.O. Bi-directional Loading of RC Beam-Column Joints[J]. Earthquake Spectra, 1986, 2(3): 537-564. [9] Shahrooz B.M. and Moehle J.P. Seismic Response and Design of Setback Buildings[J]. Journal of Structural Engineering, 1990, 116(5): 1423-1439. [10] Paulay T. Developments in the Design of Ductile Reinforced Concrete Frames[J]. Bulletin of the New Zealand National Society for Earthquake Engineering, 1979, 12(1): 35-43. [11] Ammerman O.V. and Wolfgram-French C. R/C Beam-Column-Slab Subassemblages Subjected to Lateral Loads[J]. Journal of Structural Engineering, 1989, 115(6): 1298~1308. [12] Cheung P.C., Paulay T. and Park R. New Zealand Tests on Full-Scale Reinforced Concrete Beam-Column-Slab Subassemblages Designed for Earthquake Resistance[R]. Design of Beam-Column Joints for Seismic Resistance, SP-123, American Concrete Institute, Farmington Hills, Mich., 1991: 1~38. [13] 吴勇, 雷汲川, 杨红, 白绍良. 板筋参与梁端负弯矩承载力问题的探讨[J]. 重庆建筑大学学报, 2002, 24(3): 33~37. [14] Building Code Requirements for Structural Concrete (ACI 318-02) and Commentary (ACI 318R-02) [S]. ACI Committee 318, 2002. [15] Building Code Requirements For Structural Concrete (ACI 318-02) And Commentary (ACI 318R-02)[S]. ACI Committee 318, 2002. |